TECHNICAL SPECIFICATIONS OF AMSTRAD ONE-WAY CASSETTE AIR CONDITIONER | |||
MODEL NUMBER | AMS1WC24iA | ||
TONNAGE | 2.0T | ||
TYPE OF AC | Inverter | ||
POWER SUPPLY | V-Ph-Hz | 230V,1Ph, 50Hz | |
CAPACITY (RATED) – MAX / FULL / MIN | COOLING | W | 7700 / 7000 / 3500 |
POWER INPUT (RATED) – FULL / HALF | COOLING | W | 2150 / 705 |
ANNUAL POWER CONSUMPTION | kWh | 1259.81 | |
ISEER | W | 4.30 | |
STAR RATING | 3 Star | ||
MODES | Cool, Dry, Fan, Auto | ||
CONTROLLER | Remote Control | ||
INDOOR UNIT | |||
AIRFLOW RATE (HI/MI/LO) | m³/min | 15.7 / 14.9 / 13.9 | |
AIRFLOW RATE | f³/min (CFM) | 554 / 525 / 490 | |
FAN MOTOR | Type | BLDC | |
SOUND LEVEL | dB(A) | 53 | |
MACHINE DIMENSIONS | (L*W*H) | 1180 x 450 x 132 | |
MACHINE PACKING DIMENSIONS | (L*W*H) | 1335 x 440 x 385 | |
PANEL DIMENSIONS | (L*W*H) | 1420 x 500 x 34 | |
PANEL PACKING DIMENSIONS | (L*W*H) | 1440 x 540 x 240 | |
PIPING CONNECTION (OUTER DIA.) | Liquid | mm (inch) | 9.52 |
Gas | mm (inch) | 12 | |
Drain Pipe | mm | 25 | |
INDOOR MACHINE WEIGHT (NET/GROSS) | (Kg) | 15.9 / 18.8 | |
INDOOR PANEL WEIGHT (NET/GROSS) | (Kg) | 3.6 / 6.1 | |
OUTDOOR UNIT | |||
SIZE | 26″ | ||
COMPRESSOR TYPE | Rotary | ||
REFRIGERANT | R32 | ||
REFRIGERANT CHARGE VOLUME | (Kg) | 1.1 | |
HEAT EXCHANGER | Type (Coating) | Bare | |
FAN MOTOR | Type | BLDC | |
SOUND LEVEL | dB(A) | 66 | |
DIMENSIONS | (L*W*H) | 910 x 320 x 670 | |
PACKING DIMENSIONS | (L*W*H) | 1037 x 458 x 761 | |
MACHINE WEIGHT (NET/GROSS) | (Kg) | 40.4 / 46.0 | |
MAX. INTERUNIT PIPING LENGTH | (m) | 10 Meter | |
MAX. INSTALLATION LEVEL DIFFERENCE | (m) | 5 Meter | |
PIPING CONNECTION (OUTER DIA.) | Liquid | mm (inch) | 9.52(3/8) |
Gas | mm (inch) | 12.57(1/2) | |
PIPING LENGTH | Min / Max | m | 5 meter / 15 meter |
OPERATING AMBIENT TEMP OUTDOOR COOLING (MIN ~ MAX) | °CDB | 20⁰C ~ 55⁰C |
NOTE:
- The images shown are for graphical representation only.
- Amstrad Air Conditioners are designed to work in ambient temperature upto 52 degree centigrade
- There is a continual improvement process for the better performance, changes in design and specifications can be made without prior notice.
- Noise level to be experienced from the distance of one meter from air conditioner.
- All tests are carried at standard conditions.